» This skylight system allows for an easy integration of our veranda systems, our hinged windows or our sliding window/door systems.
» It allows the possibility of adding a motorized top hung projecting opening in roof areas
Technical data
» Glazing
Fixed
Maximum 1.97"
Minimum 0.94"
Window roof
Maximum 1.50"
Minimum 0.94"
» Opening possibilities
Motorized top hung projecting
» Sections
Mullion 2.05"
Transom 2.05"
» Profile thickness
Mullion 0.083" and 0.118"
Transom 0.083"
» Minimum incline / slope
Pt = 12% (7º)
» Maximum incline / slope
Pt = 85% (40º)
» Finishes
Powder coating / Anodized
Test Center
» Transmittance
Ucw from 0.6 (W/m²K)
Please consult dimensions and glazing
» Air permeability
(EN 12152) CLASS AE
» Water tightness
(EN 13114) CLASS RE1500
» Wind resistance
(EN 13116) APT
(Design winload 2000 Pa - security wind load 3000 Pa). Test reference 118.11" × 137.80"
Projecting opening test
» Air permeability
(EN 12207) CLASS 4
» Water tightness
(EN 12208) CLASS E2200
» Wind resistance
(EN 12210) C5
Reference test 48.43" x 58.27" 1 sash.